Navien Water Heater E10 – Your Step-By-Step Troubleshooting Guide

There’s nothing quite like the jolt of a cold shower on a day you were expecting a warm one. You head to your Navien tankless water heater, and there it is—a blinking “E10” error code on the display. It’s a frustrating moment, and it’s easy to assume the worst (and a costly repair bill).

I’m here to tell you that, as an HVACR technician, I see this issue all the time. The good news is that a navien water heater e10 error is often something you can investigate and even fix yourself safely in just a few minutes.

We promise this guide will walk you through exactly what that error code means, how to perform safe and simple checks, and when it’s the right time to call in a professional. We’ll cover everything from simple outdoor blockages to best practices for preventing this error from ever coming back.

Let’s get that hot water running again. You can do this.

What Does the Navien Water Heater E10 Error Actually Mean?

Before we dive into fixing things, let’s understand the problem. The Navien E10 error code points to an issue with abnormal air pressure. Think of your tankless water heater like a living organism—to work correctly, it needs to breathe in and breathe out.

It pulls in fresh air from outside through an intake pipe to safely combust fuel and heat your water. Then, it pushes the exhaust fumes safely outside through an exhaust pipe. The E10 code is a safety alert that tells you this breathing process has been compromised.

Your unit’s internal pressure sensor has detected that air isn’t moving as it should. As a safety precaution, the system shuts down to prevent any harmful exhaust from building up. So, while it’s an inconvenience, this error is actually your water heater doing its job to keep you safe.

Common Problems with Navien Water Heater E10: Your First-Check Safety List

Don’t worry—you don’t need a truck full of tools for these first steps. Most E10 errors start with a simple blockage. We’ll walk through a few safe checks together. This is the core of our navien water heater e10 guide.

Step 1: Inspect Your Exterior Vents (The #1 Culprit)

This is, without a doubt, the most common cause of an E10 error. Your water heater’s intake and exhaust pipes (usually two white PVC pipes) terminate on the outside of your home. They are prime targets for getting blocked.

  1. Locate the Vents: Find where the two PVC pipes exit your house. This is typically on a side wall near the water heater itself.

  2. Look for Obvious Blockages: Carefully inspect the openings of both pipes. Common culprits include:

    • Snow, especially after a heavy snowfall or drifting.
    • Ice buildup during freezing weather.
    • Leaves, grass clippings, or other yard debris.
    • Bird nests, insect nests, or small animals seeking shelter.
    • A plastic bag or other trash blown against the vents.
  3. Gently Clear Any Obstructions: If you see anything blocking the pipes, carefully remove it. Use your hands or a small brush. Never poke anything deep into the pipes, as you could damage internal components.

Once the vents are completely clear, head back to your unit and try resetting it. For many homeowners, this simple step is all it takes to solve the problem.

Step 2: Check the Condensate Drain Line

High-efficiency condensing water heaters like your Navien produce condensation (water) as a byproduct of heating. This water exits through a small tube, called a condensate line, which usually drains into a floor drain or pump.

See also  Navien Hot Water Heater Manual - Unlock Efficiency, Fix Problems, And

If this line gets clogged or frozen, water can back up into the unit’s exhaust system, tripping the pressure sensor and causing an E10 error. Check the clear plastic trap and the tubing for any visible blockages or kinks. If it’s frozen in a cold climate, you may need to gently warm the line to clear it.

Step 3: Consider Environmental Factors (Like High Winds)

Sometimes, the issue isn’t a physical blockage but Mother Nature herself. Extremely high winds can create unusual pressure around the vent terminations, fooling the air pressure sensor into thinking there’s a blockage.

If you’re experiencing an E10 error during a severe windstorm, it might be a temporary issue. Wait for the wind to subside and then try resetting the unit. If the error doesn’t return, the wind was likely the cause.

How to Safely Reset Your Navien Water Heater After an E10 Code

After you’ve cleared any potential blockages, you’ll need to reset the unit to clear the code and see if your fix worked. This is one of the most useful navien water heater e10 tips.

  1. Press the power button on the front control panel to turn the unit off.

  2. Wait about 30 seconds to allow the internal controls to fully reset.

  3. Press the power button again to turn the unit back on.

The unit will go through its startup sequence. If the E10 error does not reappear and you hear it fire up, you’ve likely solved the problem! If the code comes back right away, it’s a sign that the problem lies elsewhere.

A critical pro tip: Do not repeatedly reset the unit if the error persists. This will not fix the underlying issue and could potentially cause more stress on the components.

When DIY Fixes Aren’t Enough: Knowing When to Call a Pro

You’ve done your due diligence, and that’s fantastic. But some issues are best left to a licensed and insured technician who has the right tools and training to diagnose internal problems safely.

It’s time to call a professional if:

  • The E10 error code returns immediately after you’ve cleared the vents and reset the unit.

  • You can’t find any visible obstructions in the vents or condensate line.

  • You hear rattling, grinding, or other unusual noises coming from the unit, which could indicate a failing ventor fan motor.

  • Your vent pipes appear to be damaged, disconnected, or improperly sloped.

  • You are simply not comfortable performing any of these checks yourself. Your safety is always the top priority.

A technician can test internal components like the air pressure switch, the fan motor, and the main control board to pinpoint the exact cause of the pressure fault.

Navien Water Heater E10 Best Practices: A Proactive Care Guide

The best way to deal with an E10 error is to prevent it from happening in the first place. Following a simple navien water heater e10 care guide will improve reliability and efficiency.

Make Vent Checks a Seasonal Habit

Incorporate checking your Navien’s vents into your regular home maintenance routine. In the fall, check for leaves. In the winter, make it a habit to clear snow away from them after every storm. In the spring, check for animal or insect nests.

See also  Navien Npe-240A-A Tankless Gas Water Heater Installation - Your Pro

The Importance of Annual Professional Maintenance

This is the single most effective thing you can do for the health of your water heater. During an annual service, a technician will do more than just check the vents. They will clean the heat exchanger, test all sensors, inspect the burner assembly, and ensure the unit is running at peak efficiency.

This not only prevents errors like the E10 but also extends the lifespan of your investment and keeps it running safely.

Maintaining Efficiency for a Sustainable and Eco-Friendly Home

A properly functioning water heater is an efficient one. When your unit can “breathe” correctly, it uses the optimal amount of fuel to heat your water, reducing waste. Resolving a navien water heater e10 error promptly is not just about getting your hot water back; it’s about ensuring your appliance runs as designed. This is a key part of having a sustainable and eco-friendly navien water heater e10 solution—making sure it works right!

Frequently Asked Questions About the Navien Water Heater E10 Error

Can I still use my hot water when the E10 error is showing?

No. The E10 code triggers a system lockout, meaning the water heater will not operate until the error is cleared. This is a safety feature to prevent it from running with a compromised venting system.

How much does it cost to fix a Navien E10 error?

The cost can range from $0 if it’s a simple blocked vent you can clear yourself, to a service call fee (typically $100-$200) for a technician to diagnose it. If a part like a fan motor or pressure switch needs replacement, the cost could be several hundred dollars, depending on parts and labor in your area.

Could a dirty flame sensor cause an E10 error on my Navien?

This is a great question, but no. The E10 error is exclusively related to air pressure issues within the intake/exhaust system. Problems with ignition or flame sensing would trigger different error codes on your Navien unit.


Tackling a water heater error code can feel intimidating, but you’ve just learned how to handle the most common cause of the Navien E10 error like a pro. By starting with the simple, safe checks—inspecting your vents and condensate line—you can often solve the problem yourself and save a service call.

Remember to prioritize safety, and never hesitate to call a qualified technician if the problem persists. You’ve got this!

Stay safe and stay comfortable!

David Clark